Wood Borers and Termites are known as "Silent Destroyers" because of their ability to chew through wood, flooring and even wallpaper undetected. They can damage decorative woodwork, musical instruments, wooden tools and on a more serious scale wood flooring, joinery and structural timbers. The best way to stop termites and wood borers from destroying homes and furniture is by applying chemical barrier of Bithrin 25 termiticide in the soil around the structure. It is 2.5% emulsifiable concentrate (EC) with Bifenthrin w/w as an active ingredient.
Specification
Name
Bithrin 25
Composition
Bifenthrin 2.5% EC
Model of Action
Contact
Category
Public Health Pesticides
Subcategory
Termite Control
Package
Features
HOW TO USE BITHRIN 25 FOR WOOD BORER
FOR THE
CONTROL OF WOOD BORERS IN PLYWOOD, VANEER AND WOOD
Plywood:
¨
Apply
400ml formulation/m3 of wood as glue line poisoning.
¨
Mix
1 litre of formulation in 99 litres of water/kerosene to make 0.025% solution
and applied by dipping method.
Veneer:
¨
Mix
1 litre of formulation 99 litres of water/kerosene to make 0.025% solution and
applied by dipping method.
Wood:
¨
Mix
1 litre of formulation 99 litre of water/kerosene to make 0.025% solution and
applied
HOW TO USE BITHRIN 25 FOR TERMITE
TREATMENT
DOSAGE:
¨
20
ml Bithrin 25 diluted in 1 Litre of water.
Pre-construction
Treatment & Post-construction Treatment. Treatment should be as per IS
6313 (Part-2): 2001 for pre-constructional chemical treatment measures and IS
6313 (Part-3): 2001 for post-construction treatment of the existing building
A) PRE-CONSTRUCTION TREATMENT
Treatment
should be as per IS 6313 (Part-2): 2001 for Pre-construction treatment.
¨
Treatment
of masonry foundation: Bottom surface and sides of foundation pits upto a
height of 30 cm Should be treated @ 5 ltr Chemical solution per sq.mtr of
surface area.
¨
Refill
Earth: Back fill earth in immediate contact with the foundation structure
should be treated @ 7.5 ltr per sq. mtr of the vertical surface of the
substructure for each side.
¨
Treatment
of RCC Foundation: Treatment should start at a depth of 50 cm below ground
level @ 7.5 ltr per sq.mtr.
¨
Treatment
of Top surface of plinth filling: The top surface of the consolidated earth
within plinth walls shall be treated with Chemical solution at the rate of 5
ltr/m2 of the surface before the sand bed or sub-grade is laid.
¨
Soil
treatment along external perimeter of building: Earth along the external walls
of the building should be rodded at intervals of 15 cm and to a depth of 30 cm
exposing the foundation wall surface chemical solution should be poured along
the wall @ 7.5 ltr per sq.mtr of vertical surface.
¨
Treatment
of soil under apron along external perimeter of building: Top surface of the
earth over which the apron is to be laid shall be treated with chemical
solution @ 5 ltr per sq.mtr of the vertical surface.
B) POST-CONSTRUCTION TREATMENT
Treatment
should be as per IS 6313 (Part-3): 2001 for post-construction treatment.
¨
Soil
treatment along external perimeter of building: Earth along the external walls
of the building should be rodded at intervals of 15 cm and to a depth of 30 cm
exposing the foundation wall surface. chemical solution should be poured along
the wall @ 7.5 ltr per sq.mtr of vertical surface.
¨
Treatment
of soil under apron along external perimeter of building: Top surface of the
earth over which the apron is to be laid shall be treated with chemical
solution @ 5 ltr per sq.mtr of the vertical surface.
¨
Treatment
of soil under floor: To prevent entry of termites from cracks, soil under floor
should be treated. Drill 12 mm holes at the junction of floor and wall at 30 cm
interval to reach the soil below. Squirt the chemical solution @1ltr. / Hole
and seal.
¨
Treatment
of voids in masonry: The movement of termites through masonry walls may be
restricted by drilling holes in masonry wall at abot 45° angle preferably from
both sides of the plinth wall at 30 cm interval and squirt the chemical in
holes till refusal and seal the holes.
¨
Treatment
of upper floors: In case of infestation in upper floors, treat ground floor of
the existing building as described above.
SYMPTOMS OF POISONING:
¨
Symptoms
of overexposure include bleeding from the nose, tremors and convulsions.
contact with this product may occasionally produce skin sensations such as
reshes, numbing burning or tingling, these skin sensations are reversible and
usually subside within 12 hours.
| Crop(s) | Common Name of Pest | AI (g) | Formulation (ml) | Dilution in Water (L) | Waiting Period between last spray to harvest (days) | Re-entry after each Application (In Hours) |
|---|---|---|---|---|---|---|
| Chickpea | Fruit borer & Thrips | 7.13 | 375 | 500 | 14 | - |
| Chilli | Bollworms | 7.13 | 375 | 500 | 14 | - |
| Cotton | Leaf folder & hispa | 7.13 | 375 | 500 | 14 | - |
| Paddy | Green semilooper, Pod borer, Girdle beetle and Tobacco caterpillar | 7.13 | 375 | 500 | 14 | - |
| Soybean | Fruit borer | 7.13 | 375 | 500 | 14 | - |